90,000 #/Hr Victory Boiler, 950 PSI MAWP; 650°F Superheat; Year 2018; Model VS-5-78SP-SH

467230
90,000 #/Hr Victory Boiler, Model VS-5-78SP-SH; 837 PSIG Operating Pressure; 526°F Temperature; Year 2018 with COEN Natural Gas, Low NOx Burner. One (1) Shop Assembled Voyager Steam Generator; Heating Surface: Total 7344 Sq.Ft.; Superheater Surface: 980 Sq.Ft.; MAWP: 950 PSIG @ 650°F; Operating Pressure: 837 PSIG @ 526°F; Hydrostatic Test: 1425 PSIG. Feedwater Temperature: 227°F @ Control Valve; Fuel: Natural Gas; Installation: Outdoors; Empty Weight: 186,900 Lbs.; Flooded Weight: 232,000 Lbs.

800 HP Cleaver Brooks Boiler; 150 PSI; Year 2000

467115
800 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2000; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Pumps Available Separately.

4.6 MW Solar Turbines, Model Centaur 50-6201; Two (2) Available

142068
Two (2) 4.6 MW Solar Turbines, Model Centaur 50-6201. Designed for Dual Fuel operation, (#2 Oil / Gas); Unused (New) Surplus; SoLoNOx Combustion System, 25/96 ppm NOx, Dual Fuel; Engine Model 6201SA. Generators are by Kato, 4160 V, 60 Hz, 1800 RPM. Direct Drive AC Start System.

77,000 Lb/Hr. Nebraska Boiler; MAWP: 300 PSI; Low NOx

467140
77,000 Lb/Hr. Nebraska Boiler Model: NS-E-63; MAWP: 300 PSI; Year 1996. Low NOx Coen Burner. BMS 2000 Burner Controls. Natural Gas Fired; Water Tube Boiler Design; Surface Area: 5346 Sq. Ft.; Economizer and Stack Included. DA Tank and Feedwater Pumps Available Separately.

150,000 lb/hr. Cleaver Brooks Boiler; CW-NB-500D-110; Watertube boiler, 600 PSIG; Year 2020

467300
150,000 lb/hr. Cleaver Brooks Model CW-NB-500D-110 D-Type Watertube boiler, Year 2020. Unit rated 150,000 lb/hr at 600 PSIG. Has 7,680 sq ft heating surface. Steel drum is 22.062 inside diameter X 37'-4" long. Boiler tubes are 2" OD, 0.135 MW thickness. Waterwall Headers are (2) FR 3.826" ID Pipe, (1) BR 3.826 ID Pipe, and (1) AD 2.9" ID Pipe. Waterwall tubes are 2" OD. Has an Economasters, LLC economizer. Max rated working pressure 750 PSI, heating surface 13149 sq. ft. Unit equipped with Industrial Burner Model NCB-290-G6B-003-S09-000 Fuel type #1 Natural Gas, Fuel type #2 Light Oil #2.

500 HP Cleaver Brooks Boiler; 150 PSI; Year 2003

467110
500 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2003; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Economizer / Pumps Available Separately.

5000 PPH Cleaver Brooks FLX 700/600 Water Tube Boiler

467028
Cleaver Brooks Model: FLX 700/600 Water Tube Boiler. 4,950 Lb/Hr. Steam Capacity, 150 PSI Pressure, Year 2019. Fuel: Natural Gas, Rated at 6,000,000 BTU/hr., Quantity Two (2).