Used Industrial Process Equipment Available Worldwide.
Search

Industrial Process Equipment

Industrial Exchange Network on the web advertising used industrial machinery and equipment since 1996.  Inquire today.  

Register your name and contact information to save time.  Feel free to contact us by email or phone at 804-608-0141.  View our Industry Specific Sites for additional equipment listings relevant to your purchase requirements.
Featured products

Sulzer VS6 Vertical Centrifugal Pump API

126310
Sulzer VS6 Vertical Centrifugal Pump API 610 NEW Surplus 4200 GPM 250-1500 Ft. Head. Quantity Two (2) Available API Oil & Gas Booster Pumps. Year 2016. API 610 11th ed. Model - SJD 24DLC-18QLC Max: 7 stages Material Class S-6 – Carbon Steel / Martensitic Stainless Steel. Flow Characteristics depend on number of Stages. Mechanical seals by John Crane API 682 2nd ed. Motor Available Separately: 3500 HP GE MV electric motor TEAAC API 541 4th ed. - 1800rpm 6300V/3PH/60 Hz Suitable to operate with variable frequency drivers. Includes 2 Year Spares. Pump Dimensions (m): 9.40 x 1.35 x 1.01; Motor Dimensions (m): 4.30 x 2.70 x 2.70; Unit weight: Pump: 4090 kg; Motor: 12500 kg. API 670 5th ed. - Equipment panel with MMS.

90,000 #/Hr Victory Boiler, 950 PSI MAWP; 650°F Superheat; Year 2018; Model VS-5-78SP-SH

467230
90,000 #/Hr Victory Boiler, Model VS-5-78SP-SH; 837 PSIG Operating Pressure; 526°F Temperature; Year 2018 with COEN Natural Gas, Low NOx Burner. One (1) Shop Assembled Voyager Steam Generator; Heating Surface: Total 7344 Sq.Ft.; Superheater Surface: 980 Sq.Ft.; MAWP: 950 PSIG @ 650°F; Operating Pressure: 837 PSIG @ 526°F; Hydrostatic Test: 1425 PSIG. Feedwater Temperature: 227°F @ Control Valve; Fuel: Natural Gas; Installation: Outdoors; Empty Weight: 186,900 Lbs.; Flooded Weight: 232,000 Lbs.

6745 kw Siemens SST-110 Steam Turbine Generator, Year 2018

467235
6745 kw Siemens SST-110 Steam Turbine Generator, Year 2018. Single Stage Back Pressure Turbine Design. Inlet Steam: 90,000 #/hr Steam at 850 PSI and 650 F. Exhaust Steam: 90,000 #/hr at 46 PSI and 375 F. Exhaust Steam Pressure is variable depending on process conditions. Includes: 8750 KVA AC Synchronous Generator Manufactured by TD Power Systems, Type TC150. Capacity: 7.0 MW / 13.8kV / 60 Hertz. Year 2018. System used less than one year due to complete plant closure. All controls and MCC panels are available. Desuperheater is available to control exhaust steam temperature. SPARE TURBINE ROTOR ASSEMBLY INCLUDED.

800 HP Cleaver Brooks Boiler; 150 PSI; Year 2000

467115
800 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2000; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Pumps Available Separately.

74500 Lb/Hr. Nebraska Boiler Model: NS-E-66 Water Tube Boiler

126220
74500 Lb/Hr. Nebraska Boiler Model: NS-E-66 Water Tube Boiler Design Pressure: 250 PSI Year 1993. Natural Gas Fired Boiler Sq. Ft.: 4873 Economizer and Stack Included. DA Tank and Feedwater Pumps Available Separately.

80000 Lb/Hr. Nebraska Boiler Model NS-F-72 Water Tube Boiler

126221
80000 Lb/Hr. Nebraska Boiler Model NS-F-72 Water Tube Boiler Design Pressure: 250 PSI Year 1998. Natural Gas Fired Coen DFL-600 Burner Boiler Surface Sq.Ft.: 6474. Includes ERI Economizer Stack FD Fan and Motor. Boiler Design Capacity: 100000 Lbs/Hr. is limited by Burner / Fan size to 80000 Lb/Hr. All Available Drawings and Engineering Included. Feedwater Pumps and DA Tank Available Separately. Three (3) Identical Boilers Available as part of Complete Steam Plant.

Falk Model 1110YF-1LS Gear Reducer. HP: 1000; Ratio: 1.019; Input RPM:

123143
Falk Model 1110YF-1LS Gear Reducer. HP: 1000; Ratio: 1.019; Input RPM: 1020; Output RPM: 1001; Type: Parallel; S.F.: 2. Notes: GallonCapacity 19.0; MillNumber 46-50-1965; Date 1/95 Falk Rebuilt Tag 3/95

4.6 MW Solar Turbines, Model Centaur 50-6201; Two (2) Available

142068
Two (2) 4.6 MW Solar Turbines, Model Centaur 50-6201. Designed for Dual Fuel operation, (#2 Oil / Gas); Unused (New) Surplus; SoLoNOx Combustion System, 25/96 ppm NOx, Dual Fuel; Engine Model 6201SA. Generators are by Kato, 4160 V, 60 Hz, 1800 RPM. Direct Drive AC Start System.

655 kW (878 HP) Turbosteam Steam Turbine

467050
655 kW Steam Turbine with Generator. System includes, Dresser-Rand Coppus RLHA 24 Turbine, Marathon Synchronous Generator, and Lufkin Speed Reducing Gearbox. Year 2013. Turbine Generator Skid: A common steel base is provided for the turbine, speed reducing gear and generator. The turbine and gear are coupled with a Lovejoy flexible stainless steel disc spacer type coupling, dynamically balanced to a maximum 2.5 mm/sec of vibration and meeting ISO G2.5. The generator and gear are coupled with a Lovejoy gear-type coupling with a 1.5 service factor. Coupling guards are installed over both couplings. Skid piping includes all piping necessary to collect condensate drains, steam leak offs and instrument air to single field connection point. Manual globe valves are installed in condensate drain lines for startup condensate removal. Skid wiring includes all conductors and conduit necessary to consolidate terminations for all skid instrumentation and control devices in a common terminal box.

7.4 MW Taurus 70 Gas Turbine Generator

467060
7.4 MW Solar Taurus 70 Combustion Turbine Generator Package; Engine: T10801SA; SoloNox - Low NOx engine designed for Natural Gas fuel combustion. Hours: 12,205; Starts @ 125; Includes 7600 kw Kato Synchronous Generator; 12.47 kV; 9500 KVA; 3 Phase; 60 Hertz. Featuring on Package Controls, and a Donaldson Inlet Air Filter with Air Inlet Chiller. *** Also available are two (2) absorption chillers rated for 2000 Tons of cooling, an ammonia SCR and Catalyst system, as well as a Rentech hot water waste heat recovery boiler ***

Donaldson - Turbine Air Inlet Filter

467061
Donaldson Air Inlet Filter designed for operation with the Taurus 70 Solar Gas Turbine. Built for Solar Turbines. Includes Chiller for Inlet Air to keep temperature at 59F. Year NOV 2011. Weight 5783 Lbs. Dry / 7983 Wet.

1015 Ton Absorption Chillers, Qty (2), Series 5G

467062
Two (2) Thermax, Series 5G, single effect hot water driven vapor absorption chillers engineered to each produce 1015 tons of chilled water at 42 °F of using 17,374 MBH of recovered heat from a waste heat hot water boiler. Thermax Absorption Chillers, New 2012. The chillers will be capable of operating in-series as well as in parallel mode.

Rentech Waste Heat Recovery Boiler

467063
WHRU – Rentech Hot Water Boiler rated for 690,000 lbs. water an hour (1,377 GPM). A combustion exhaust stream is used to heat approximately 690,000 pounds of water per hour from 170 °F to 225 °F at an ambient condition of 55 °F. Designed for use with a Solar Turbines, Taurus 70 Gas Turbine Generator.

932 HP Elliott Steam Turbine Generator

467135
932 HP Elliott Steam Turbine with 655kw WEB Induction Generator. Year 2014. Turbine and Generator are mounted on a steel base frame. Turbine is powered by a Biomass Steam Plant. Steam conditions: 50,000 lb/hr. at 400 PSI / 448F Temperature. Inlet: 400 PSI; Exhaust: 150 PSI; Turbine speed: 3628 RPM.

77,000 Lb/Hr. Nebraska Boiler; MAWP: 300 PSI; Low NOx

467140
77,000 Lb/Hr. Nebraska Boiler Model: NS-E-63; MAWP: 300 PSI; Year 1996. Low NOx Coen Burner. BMS 2000 Burner Controls. Natural Gas Fired; Water Tube Boiler Design; Surface Area: 5346 Sq. Ft.; Economizer and Stack Included. DA Tank and Feedwater Pumps Available Separately.

Quantity (2); Model VAZ 300 / 250 UNF Vecoplan Shredders

467280
Quantity (2); Model VAZ 300 / 250 UNF Vecoplan Shredders; 5344-010 Machine Number; Rebuilt “As New” In 2022; Mfg. Year 2001; Rotor: 620mm Diameter; 2491mm Length; Speed: 142 RPM; Main Drive: Electric Motor with Fluid Coupling, Joint Shaft, Two Step Spur; Spur Gear Ratio: 12.5 to 1; Nominal HP: 192 Kw; Nominal Amps: 332A; Motor RPM: 1782; Electricals: 460V / 3 Ph / 60 Hz.

500 HP Cleaver Brooks Boiler; 150 PSI; Year 2003

467110
500 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2003; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Economizer / Pumps Available Separately.

5000 PPH Cleaver Brooks FLX 700/600 Water Tube Boiler

467028
Cleaver Brooks Model: FLX 700/600 Water Tube Boiler. 4,950 Lb/Hr. Steam Capacity, 150 PSI Pressure, Year 2019. Fuel: Natural Gas, Rated at 6,000,000 BTU/hr., Quantity Two (2).

200 HP Falk Model 2120Y2-LS; Ratio: 26:15

467150
200 HP Falk Model 2120Y2-LS; Ratio: 26:15; MO# 90-165222; RPM IN: 1785; Cat. HP Rating: 200; RPM. OUT: 68.3; S.F.: 1.46.

GENERAL ELECTRIC Gearbox; HP: 14500; Model: S-238-N ; Ratio: 1.4; RPM

121569
GENERAL ELECTRIC Gearbox; HP: 14500; Model: S-238-N ; Ratio: 1.4; RPM In: 4920; RPM Out: 7194; S.F.: 0

ELLIOTT Gearbox; 372 HP; Model: C-1 ; Ratio: 2.03; RPM In: 1770; RPM

121240
ELLIOTT Gearbox; 372 HP; Model: C-1 ; Ratio: 2.03; RPM In: 1770; RPM Out: 354; S.F.: 1.3

TURBODYNE Gearbox; HP: 2190; Model: H-5 ; Ratio: 2.239; RPM In: 40.3;

122345
TURBODYNE Gearbox; HP: 2190; Model: H-5 ; Ratio: 2.239; RPM In: 40.3; RPM Out: 1800; S.F.: 0

ELLIOTT Gearbox; HP: 385; Model: C-2 ; Ratio: 2.48; RPM In: 4.2; RPM

121316
ELLIOTT Gearbox; HP: 385; Model: C-2 ; Ratio: 2.48; RPM In: 4.2; RPM Out: 1730; S.F.: 1.3

ELLIOTT Gearbox; HP: 800; Model: C-5 ; Ratio: 2.5; RPM In: 4500; RPM

121356
ELLIOTT Gearbox; HP: 800; Model: C-5 ; Ratio: 2.5; RPM In: 4500; RPM Out: 1800; S.F.: 1

ELLIOTT Gearbox; HP: 625; Model: C4R4 ; Ratio: 0; RPM In: 4514; RPM O

121342
ELLIOTT Gearbox; HP: 625; Model: C4R4 ; Ratio: 0; RPM In: 4514; RPM Out: 1000; S.F.: 2.41

ELLIOTT Gearbox; HP: 485; Model: C-5 ; Ratio: 5.03; RPM In: 4388; RPM

121333
ELLIOTT Gearbox; HP: 485; Model: C-5 ; Ratio: 5.03; RPM In: 4388; RPM Out: 868; S.F.: 1.5

ELLIOTT Gearbox; HP: 600; Model: C-7 ; Ratio: 8.03; RPM In: 4690; RPM

121341
ELLIOTT Gearbox; HP: 600; Model: C-7 ; Ratio: 8.03; RPM In: 4690; RPM Out: 600; S.F.: 1.1

CLEVELAND Model 417F Worm Gear Speed Reducer Ratio 12-1Lh Size 300Atw

123764
CLEVELAND Model 417F Worm Gear Speed Reducer Ratio 12-1Lh Size 300Atw 8.7 Hp 300 Rpm Service Factor 1.2 Cast Iron Material